Tilting Flume


The whopping array of Tilting Flume is accessible under cap of Universal Motion Inc. even a special gamut of Hydraulic Tilting Flume is high in demand in India as well as in foreign countries.The best price tags for Tilting Flume are offered by us only that must suit the budget of our clients. Lastly, we are the renowned Tilting Laboratory Flume Manufacturer and one of the superior Exporters from India.

TIF- 04

INTRODUCTION

The flume consists of a channel of size as given below in the specifications. At the inlet, a flow steadying section is provided so that there will be less disturbance at the test section. The
gates provided at the upstream and downstream of the test section help to regulate the depth of flow. Depth measurements can be achieved with the help of a hook or point gauge mounted on a trolley which gives longitudinal and transverse movement. The slope of the bed can be adjusted, manually or electrically, to give positive or negative slopes.

FEATURES

  • An arrangement to obtain quiescent flow.
  • Gates for regulating the depth of flow, one at the upstream and the other at the downstream
  • A point gauge trolley for depth measurement.
  • Tilting bed.
  • Models of Sharp crested, Broad crested and Ogee weir, Venturi flume, and Spillway.( Optional At an Extra Cost)
  • Transparent middle half test section for visualisation of flow over test section - 6 mtrs. In Length of perspex sheet.

  • RANGE OF EXPERIMENTS

  • Study of Open Channel flow with slope.
  • Study of Specific Energy Curve.
  • Study of Hydraulic Jump.
  • Study of Nappe Profiles over a Sharp Crested Weir. Optional if models are provided
  • Calibration of Sharp Crested, Broad Crested and Ogee Weir. Optional if models are provided
  • Calibration of a Venturi Flume. Optional if models are provided.

  • SPECIFICATIONS

  • Length : 10 Meters.
  • Width : 30 cms.
  • Depth : 60 cms.
  • Sides : Provided with transparent 6 mm. thick Perspex sheet, 5 meters long on both the Sides.

  • A hook gauge mounted on a trolley, digital vertical and horizontal measurement with computer interface.
  • Trolley movement by slow speed motor with limiting safety switches.
  • Orifice meter with DP transmitter with voltage output for computer interface.
  • A differential manometer for manual use.
  • Hydraulic cylinder with flow operated jack for slope adjustment.
  • A 10 HP monoblock pump with starter and foot valve.
  • Slope measurement with potentiometer and analog output for computer interface.
  • Computer Interface with Advantech cards to accept analog input and serial outpur for computer.
  • Computer will be provided by institute. If requested we will provide at extra cost.

  • MODELS (OPTIONAL AT EXTRA COST)

  • A model of Broad Crested Weir.
  • A model of Sharp Crested Weir.
  • A model of Ogee Shaped Weir.
  • A model of Venturi Flume.
  • A model of Standing Wave Flume.

  • INSTRUCTION MANUAL

    A technical Manual is supplied which gives details of the apparatus and procedure of Experiments. Software CD for installation of windows based software .

    SERVICES REQUIRED

  • Suitable water supply arrangement with necessary piping.
  • Suitable drainage or return gutter arrangement.
  • 3 Phase / 20 Amp power supply.
  • Floor space required - 15 X 6 meters.
  • Power Supply : 230VAC, 1 phase , Stabilised.

  • TIF- 06

    INTRODUCTION

    The flume consists of a channel of size as given below in the specifications. At the inlet, a flow steadying section is provided so that there will be less disturbance at the test section. The
    gates provided at the upstream and downstream of the test section help to regulate the depth of flow. Depth measurements can be achieved with the help of a hook or point gauge mounted on
    a trolley which gives longitudinal and transverse movement. The slope of the bed can be adjusted, manually or electrically, to give positive or negative slopes.

    FEATURES

  • An arrangement to obtain quiescent flow.
  • Gates for regulating the depth of flow, one at the upstream and the other at the downstream.
  • A point gauge trolley for depth measurement.
  • Tilting bed.
  • Models of Broad crested, Spillaway / Ogee weir and Venturi Flume
    Venturi flume, and Spillway. ( Optional At an Extra Cost)
  • Transparent middle half test section for visualisation of
    flow over test section - 5 mtrs. in Length of perspex sheet.

  • RANGE OF EXPERIMENTS

  • Study of Open Channel flow with variation in bed slope.
  • Study of Specific Energy Curve by pitot tube (optional ).
  • Study of Hydraulic Jump.
  • Study of Profiles over a Broad Crested Weir.
  • Detarmination of Coefficient of Discharge for Broad Crested and Ogee Weir.
  • Detarmination of Coefficient of Discharge of Venturi Flume.

  • SPECIFICATIONS

  • Length : 20 Meters.
  • Width : 50 cms.
  • Depth : 60 cms.
  • Sides : Provided with transparent 6 mm. thick Perspex sheet, 8 meters long on both the sides.
  • A hook gauge mounted on a trolley.
  • Venturimeter.
  • A differential manometer.
  • Hydraulic cylinder with flow operated jack.
  • A 10 HP monoblock pump with starter and foot valve.

  • MODELS(OPTIONAL AT EXTRA COST)

  • A model of Sharp Crested Weir.
  • A model of Standing Wave Flume.
  • A V Notch of 90ΓΈ and Rectangular Notch, made up of 3 mm Brass Sheet.

  • INSTRUCTION MANUAL

    A technical Manual is supplied which gives details of the apparatus and procedure of experiments.

    SERVICE REQUIRED

  • Suitable water supply arrangement with necessary piping.
  • Suitable drainage or return gutter arrangement.
  • Floor space required - 30 X 6 meters.
  • Power Supply : 440 V, 3 Phase, Stabilised.
  •  


    TIF-06-1-4  
    Tilting Flume

    + Zoom

     

    Check All | Clear All