Please Install Flash Player
Download from here

  
 
Structure Frame

Home   • ProductsEducational Laboratory Equipment • Structure Frame


It is a bit difficult task to find the qualitative Structure Frame within the medium or small budget, but we offer you extensive spectrum of Structure Frame which is the significant mark of quality and price. Moreover one can also avail the gigantic array of Structural Steel Frame at most competitive pries. In addition, we are the goliath steel structure frame manufacturer and suppliers in India.

LOF- 01

INTRODUCTION

Loading Frame is a Test Rig useful f or testing of structural elements. This self straining loading frame has been designed to cover wide range of experiments on various structural elements like columns, portal frames, Beams and other structures which can be accommodated and tested within the space
and rated capacity of the frame.
The frame is fabricated from standard rolled steel section of suitable sizes for assured strength.
BASIC FRAME :It is designed as a self straining frame where no load is transferred to the ground, except self weight of the frame and loaded member
The frame is fabricated from standard rolled steel section of suitable sizes for assured strength.

RANGE OF EXPERIMENTS

Beams : 3m. Long.
Columns : 2m. Height.
Slab : 2. 0m. x 1.5m. approx.

SPECIFICTIONS

Top longitudinal girder.
Bottom longitudinal girder.
Columns.
Upper Cross Beams.
Bracing members.
Lateral load Beam.

MODELS (AT EXTRA COST)

Columns Caps.
Arrangement for end support for beams.
Hydraulic Jacks of suitable capacity.
Arrangement for stimulating uniformly distributed load.
Arrangement for lateral loading.
Proving rings of suitable capacity.

INSTRUCTION MANUAL

A manual is supplied which gives details of the apparatus and procedure of experiments along with specimen calculations.

SERVICE REQUIRED

1) The customer will provide the necessary foundation along with foundation bolts as per drawing that will be submitted to the customer in due course of time.
2) Necessary facility for small work of welding etc . will be provided by the customer, if required. In case it is necessary to have a substantial amount of welding work then customer will provide only 30 HP connection at the site and we will bear the charges for electrically consumed by us. Necessary
illumination at the site will be provided by the customer, so that we can work even during the night for
early completion of the work.
3) Accommodation for our supervisory staff should be provided in the vicinity of the site for effective
erection work.
Space Required : 3m .x 1 .5m. x 2.5m. Ht.

LOF- 03

INTRODUCTION

Loading Frame is a test Rig useful for testing of structural elements. This self straining loading frame has been designed to cover wide range of experiments on various structural elements like beams, columns, portal frames and other structures which can be accommodated and tested within the space and rated capacity of the frame.
The Frame Is Fabricated From Standard Rolled Steel Sections Of Suitable Sizes For Assured Strength.
BASIC FRAME :
The skeleton of basic frame is shown in fir 1. It is designed as a self straining frame where no load is transferred to the ground, except self weight of the frame.

RANGE OF EXPERIMENTS

1)Beams - 5.5 m.
2)Columns - 4 m.
3)Slab - 5m x 3m.

SPECIFICTIONS

1) Top longitudinal girder.
2) Bottom longitudinal girder.
3) Columns.
Upper cross Beams (UCB) and Lower Cross Beams (LCB) are movable members.
These members move along longitudinal direction. By means of UCB Proper placing and positioning of load is ensured. While LCB are moved is such a way to ensure proper span of the member to be tested.

INSTRUCTION MANUAL

A manual is supplied which gives details of the apparatus and procedure of experiments along with specimen calculations.

SERVICE REQUIRED

1) The customer will provide the necessary foundation along with foundation bolts as per drawing
that will be submitted to the customer in due course of time.
2) Necessary facility for small work of welding etc., will be provided by the customer if required. In case it is the customer will provided only 30 H.P connection at the site and we will bear the charges from electricity consumed by us. Necessary illumination at the site will be provided by the customer.
3) Accommodation for our supervisory staff should be provided in the vicinity of the site for effect ion
erection work.
Space Required : 6 x 4 x 4.5 ht

LOF-01

Structure Frame

Enlarge {+}

LOF-03

Structure Frame

Enlarge {+}



Select and click Select All   |   Clear All  


Choose your language :   Deutsch  English   Espanol  Francis  Italy   Portugues